A robot policy can look good on the data it learned from and still fail on a shelf it has not seen. NVIDIA’s own GR00T documents use three different kinds of measurement, and they answer different questions.

Open loop: matching recorded actions

The GR00T repository offers an open-loop evaluation that feeds recorded observations to the model and compares its predicted actions with what the demonstrator actually did, plotting both and reporting mean squared error. It is a quick check that training worked and the data is wired correctly. It cannot show whether the robot completes a task, because the robot never acts on its own predictions.

Closed loop: the robot acts

Closed-loop evaluation runs the policy in simulation or on hardware, where each action changes what the robot sees next. In NVIDIA’s end-to-end walkthrough, a sample run prints a success rate of 1.0 from a single episode. The authors call a 600-step run “a quick smoke test” and recommend 100 episodes, or 1,000 “for a stronger estimate,” with several environments in parallel for more variation between trials.

How the paper counted

The GR00T N1 paper used 100 trials per simulated task, taking “the maximum score of the last 5 checkpoints,” which follows an established RoboCasa protocol. Picking the best of five checkpoints on the test itself nudges the reported number upward. It is a common practice, and the paper discloses it.

On the physical GR-1 humanoid, most tasks were scored over 10 trials, with partial credit for completed stages. One task, packing machinery parts, got five trials “due to the time constraint.” With ten trials, a single success moves a task’s score by ten points. The repository separately warns of “5-6% variance between runs” from random image augmentation during training. Two results a few points apart may be the same result.

The paper’s generalization test comes closest to a truly unseen test set. The pretrained model was asked to put novel objects into an unseen container, five objects with three trials each, and scored 11 out of 15, or 73.3 percent. A grasp without a successful placement counted as half.

For any GR00T-based result, three facts say most of what matters: how many trials were run, whether the test conditions were kept out of training and tuning, and whether the number is open loop, closed loop in simulation or on hardware. A success rate without them cannot be compared with another.